Warning: Undefined array key "ver" in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 3
Warning: Cannot modify header information - headers already sent by (output started at /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php:3) in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 290
Warning: Undefined variable $redirectUrl in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 292
MSR Electronics GmbH
MSR145: Data Logger for Temperature, Humidity, Air Pressure, Liquid Pressure, Acceleration, Light
multifunctional data logger · large selection of sensors · various battery and housing variants · up to over 1 bn measured values · air cargo approved
Product features universal data logger MSR145
High-performance mini data logger for temperature, humidity, fluid pressure, air pressure, acceleration, light and more
Measures and records up to six different measurement parameters simultaneously
Wide range of housings, batteries, internal and external sensors, connectors (see configurator)
Freely selectable measurement rates of up to 50 values per second
3-axis-acceleration sensor ±15 g with Fast Peak (1 kHz)
Connector for thermal element of Type K
4 analog inputs available
Recording time of of up to two years, depending on the battery and the measurement rate
Lithium-polymer battery 230 mAh or 1000 mAh, rechargeable via USB port
Stores up to 2 million (internal memory) or 1 billion (microSD Card) total readings
Small in size, light in weight
Free MSR PC software: MSR Setup, Reader, Viewer and Online software
With a few clicks you are able to select and request a no-obligation quotation of your desired MSR145.
1. Select the housing and the corresponding battery.
Housing
Type and battery
Picture
Size & weight
Medium
Sheat material
Item no.
Standard IP 60
Design housing with 230 mAh battery
27 x 16 x 53 mm (W x H x L) approx. 20 g
Air
PC, not encapsulated
145B15
Design housing with 1000 mAh battery
39 x 23 x 72 mm (W x H x L) approx. 56 g
Air
PC, not encapsulated
145B7
Waterproof IP 67
Silicon tube with 230 mAh battery
20 x 14 x 62 mm (W x H x L) approx. 18 g
Air, various liquids
Silicon, encapsulated
145B4
Design housing with 230 mAh battery
27 x 16 x 53 mm (W x H x L) approx. 27 g
Air, various liquids
PC, encapsulated
145B16
Design housing with 1000 mAh battery
39 x 23 x 72 mm (W x H x L) approx. 64 g
Air, various liquids
PC, encapsulated
145B8
2. Select the configuration.
You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate
Technical data
Internal
External (according to cable length)
0.20 m
1.00 m
1.60 m
Temperature
1/s to every 12 h
Working range: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.1 °C (-25...+55 °C) ±0.3 °C (-40...+125 °C)
Item no. T9
Item no. FT9/020
Item no. FT9/100
Item no. FT9/160
Working range: -55...+125 °C Max. deviation: ±0.5 °C (10...+70 °C) ±2 °C (-55...+125 °C)
only available externally
Item no. FT2/020
Item no. FT2/100
Item no. FT2/160
Connector for thermal element of Type K (without sensor)
4/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: -200...+1350 °C
only available externally
Item no. FT3/020
Item no. FT3/100
Item no. FT3/160
Humidity with integrated temperature
1/s to every 12 h
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. Feuchte (80...100 %, +25 °C)
Item no. H3
Item no. FH3/020
Item no. FH3/100
Item no. FH3/160
Air pressure absolute, with integrated temperature
Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor)
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (1% FS) (750...1100 mbar absolute, +25 °C)
Item no. P5
Item no. FP10/020
Item no. FP10/100
Item no. FP10/160
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1% FS) (1...10 bar abs., +25 °C)
Item no. P7
only available on request
Item no. FP7/020
Item no. FP7/100
Item no. FP7/160
Fluid pressure with integrated temperature
Internal: 1/s to every 12 h External: 10/s* to every 12 h *(1/s in combination with A4 sensor)
Material in contact with media:
Stainless Steel AISI 316L (DIN 1.4404 / 1.4435)
O-rings: Viton® 70° Sh
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP9/020
Item no. FP9/100
Item no. FP9/160
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP3/020
Item no. FP3/100
Item no. FP3/160
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS)
only available externally
Item no. FP4/020
Item no. FP4/100
Item no. FP4/160
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS)
only available externally
Item no. FP8/020
Item no. FP8/100
Item no. FP8/160
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS)
only available externally
Item no. FP12/020
Item no. FP12/100
Item no. FP12/160
3-axis-acceleration (static)
50/s to every 12 h
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
3-axis-acceleration with Fast Peak (1 kHz)
50/s to every 12 h
Item no. A4
Item no. FA4/020
Item no. FA4/100
Item no. FA4/160
Light
1/s to every 12 h
Working range: 0...83'000 lx Max. sensitivity at 550 nm
Item no. L3
Item no. FL3/020
Item no. FL3/100
Item no. FL3/160
Connection for strain gauges
Characteristics:
full bridge
rated output 1 mV/V
bridge voltage 3 V
only available externally
Item no. FD/020
Item no. FD/100
Item no. FD/160
Analogue inputs (resolution: 12 bit)
50/s* to every 12 h *(1/s in combination with A4 sensor)
Input configuration:
only available externally
Exxxx/020
Exxxx/100
Exxxx/160
Control terminal
Characteristics:
Alarm output
Input for starting and stopping data recording
3 V voltage output
only available externally
Item no. FY/020
Item no. FY/100
Item no. FY/160
3. Would you like to expand the memory capacity of your MSR145 to over 1 billion measured values?
Please order the expansion slot for plugging-in a standard microSD card here.
Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)
Please note that:
this expansion slot with plugged-in microSD card only meets the protection category IP60, even with the design housing B8,
one formatted and ready for use microSD card (≥4GB) is included.
N10006
4. Contact us for prices and delivery terms!
Make a price enquiry by telephone, fax or e-mail
The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please have the codes ready.
Warning: Undefined variable $companyName in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 1277
Phone:
Warning: Undefined variable $phoneNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 1278
Fax:
Warning: Undefined variable $faxNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 1279
E-mail:
Warning: Undefined variable $emailAddress in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr145.php on line 1280
5. General technical data on the MSR145.
Memory capacity:
Over 2 million measurement values, with microSD card over 1 billion.
Key:
Set bookmark or start and stop recording.
Power supply:
Lithium-polymer battery, rechargeable via the USB port.
Interface:
USB
PC software:
Free MSR PC software for configuration and evaluation of the data. PC requirements: Windows 7 or higher.
Operating conditions:
Temperature:
-20...+65 °C
Storage conditions:
Temperature: Humidity:
+5...+45 °C (ideal storage conditions for the battery) 10...95 % relative humidity, non-condensing