MSR255 Data Logger: Robust multi-talent with LCD screen
With up to five different sensors, four additional analogue inputs and an easy to read LCD screen the compact MSR255 offers maximum possible flexibility and user-friendliness.
5 sensors, 4 analogue inputs
The measuring tasks undertaken by the user define the way in which the MSR255 is configured: There is a choice of temperature, humidity, air pressure and light sensors (fitted internally within the case or externally on a cable) together with a sensor for measuring acceleration in all three co-ordinate axes. Acceleration values can be measured at 3200 Hz and saved at a frequency of approx. 50 Hz following digital filtration. In addition, the voltage of four further external analogue channels or sensors can also be recorded. The analogue inputs feature an alarm output, multiple output switching power supply and an input for starting and stopping data recording.
The memory capacity of the MSR255 is over 2 million measurement parameters. Thanks to its high-capacity lithium polymer battery the data logger is ideal for long-term data acquisition applications. The 4-row backlit LCD display has four individually configurable views. All acquired data can be quickly transferred to a PC or laptop via the USB interface.
Configure your own custom MSR255 variant here!
With a few clicks you are able to select and request a no-obligation quotation of your desired MSR255.
1. Basic specification and technical data for the MSR255
Housing
Technical data
Item no.
Standard IP 60 not encapsulated
Housing:
Anodised aluminium industrial case with top-hat rail snapper (TS35)
Size & weight:
78 x 62 x 38 mm, approx. 222 g
Memory capacity:
Over 2 000 000 measurement parameters
Operation:
Two keys for selecting functions and controlling data recording
Display:
Four row LCD matrix display
LED:
3 colour LED to indicate data recording, alarm and charge condition
Integrated sensors:
Selection of different sensors for temperature, relative humidity, pressure, light and 3-axis acceleration/position
Measurement rate (MR):
1 /s to every 12 h (acceleration up to 3200 /s)
Storage rate (SR):
1 /s to every 12 h (acceleration up to 50 /s)
Power supply:
Rechargeable lithium polymer battery 2300 mAh, external power supply unit
Air pressure absolute, with integrated temperature
1/s to every 12 h
0...2000 mbar absolute external: -20...+85 °C internal: -20...+65 °C ±2.5 mbar (750...1100 mbar absolute, +25 °C)
Item no. P
Item no. FP/020
Item no. FP/100
Item no. FP/160
0...14 bar absolute -20...+65 °C ±50 mbar (1...10 bar abs., +25 °C)
Item no. P2
Item no. FP2/020
Item no. FP2/100
Item no. FP2/160
3-axis-acceleration
Acceleration: 50/s (3200/s) Attitude: 1/s to every 12 h
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
Light
1/s to every 12 h
0...65 000 lx max. sensitivity at 500 nm
Item no. L
Item no. FL/020
Item no. FL/100
Item no. FL/160
3. Do you require an additional 4 analogue inputs for connecting third-party sensors?
It is possible to expand the range of possible applications for which your MSR255 can be used by specifying four analogue inputs. These additional inputs allow external sensors for a wide range of measuring tasks to be connected. If required, these third-party sensors can be powered by the logger's internal battery. The power can be automatically turned on before measurements take place with a pre-settable lead time. This allows any necessary warm-up periods for the sensors to be taken into consideration.
Analogue inputs
Inputs
Input configuration
Item no.
Including an alarm output, multiple output
switching power supply and an input for
starting and stopping data recording.
Measurement/storage rate: 1/s to every 12 h
4 analogue inputs
(resolution: 12 bit)
0...3.0 V - Standard
E3333
4 analogue inputs
(resolution: 12 bit)
Select the number of inputs for the
respective input configuration:
(1)0...20 mA (2)4...20 mA (3)0...3.0 V (4)0.5...4.5 V / 0...5.0 V (5)0...10.0 V / 1.0...6.0 V (6)0...12.0 V (7)0...24.0 V (8)0...36.0 V (9)0...48.0 V
Exxxx
3. Contact us for prices and delivery terms!
Make a price enquiry by telephone, fax or e-mail
The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please have the codes ready.
Warning: Undefined variable $companyName in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr255.php on line 1013
Phone:
Warning: Undefined variable $phoneNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr255.php on line 1014
Fax:
Warning: Undefined variable $faxNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr255.php on line 1015
E-mail:
Warning: Undefined variable $emailAddress in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr255.php on line 1016