Warning: Undefined array key "ver" in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 3 Warning: Cannot modify header information - headers already sent by (output started at /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php:3) in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 37 Warning: Undefined variable $redirectUrl in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 39 MSR Electronics GmbH

MSR145WD Wireless Data Logger with BLE, Display & MSR SmartCloud

Wireless monitoring of measurement data and rapid reading of measured values – this ease of use is offered by the new MSR145WD wireless data logger. The mini-logger is equipped with Bluetooth Low Energy, a bright OLED graphic display and the optional web-based service MSR SmartCloud for data monitoring from any location.

MSR SmartCloud facilitates the storage of your measured data on a server via the Internet. The BLE wireless radio link is particularly advantageous for applications that require monitoring of measured data from locations that are difficult to access, such as machine rotations. BLE allows the user immediate data visualisation irrespective of the location. You can recall the measured values on your smartphone, receive alarm messages via MSR SmartCloud and, if required, share data from multiple MSR145WD data loggers with your team any time.

Technical data Bluetooth Low Energy
Data Logger iPhone App
  • Bluetooth Low Energy (Bluetooth 4.0 Smart) 2.4 GHz
  • Radio range: approx. 10 m
  • Communication with multiple MSR145WD data loggers possible
  • Alarm function, transmission to MSR SmartCloud
  • Free app for mobile devices (Android 4.4+, iPhone 4S+, iPad 3+)
  • Sturdy BLE receiver box available as gateway

Fast readings of measured values: MSR145WD with brilliant OLED colour display

For a compact representation of data and graphic charts, your MSR145WD is equipped with a colour OLED display. The high screen resolution facilitates easy reading of measured values, even in total darkness and from virtually any viewing angle. The display is switched on and off manually; the desired display data can be configured in the MSR PC software.

Technical data OLED display
Das OLED-Farbdisplay des MSR145-Funkdatenloggers
  • High-contrast, brilliant OLED (organic light-emitting diode) colour display to show data and graphical charts
  • Resolution: 96 x 64 pixels
  • Display area: 22.14 mm W x 15.42 mm H
  • Fast response time: <10 μs
  • Wide viewing angle >160°

Configure your own custom MSR145WD variant here!

With a few clicks you are able to select and request a no-obligation quotation of your desired MSR145WD.

  1. Select the housing and the corresponding battery.
  2. Select the configuration.
  3. Choose the FlexSensors if required.
  4. Do you require a base station to transmit the measured values to the MSR SmartCloud?
  5. The use of MSR SmartCloud.
  6. Request a no-obligation quotation!
  7. General technical data of the MSR145WD.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat
material
Item no.
Standard
IP 60
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 27 g
Air PC, not
encapsulated
145WDB25
Design housing
with 900 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 43 g
Air PC, not
encapsulated
145WDB23
Waterproof
IP 67
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 36 g
Air,
various liquids
PC,
encapsulated
145WDB26
Design housing
with 900 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 62 g
Air,
various liquids
PC,
encapsulated
145WDB22

2. Select the configuration.

You can select various internal sensors as well as up to five external sensors or connectors.

Measured parameter /
Measurement/
storage rate
Technical data Internal External (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
Working range:
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±0.1 °C (-25...+55 °C)
±0.3 °C (-40...+125 °C)
Item no. T9
Item no. FT9/020

Item no. FT9/100

Item no. FT9/160

Working range:
-55...+125 °C

Max. deviation:
±0.5 °C (10...+70 °C)
±2 °C (-55...+125 °C)
only available
externally
Item no. FT2/020

Item no. FT2/100

Item no. FT2/160

Connector for thermal
element of Type K

(without sensor)


1/s to every 12 h
Working range:
-200...+1350 °C
only available
externally
Item no. FT3/020

Item no. FT3/100

Item no. FT3/160

Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±2 % rel. humidity
(10...80 %, +25 °C)
±3 % rel. Feuchte
(80...100 %, +25 °C)
Item no. H3
Item no. FH3/020

Item no. FH3/100

Item no. FH3/160

Air pressure absolute,
with integrated
temperature

1/s to every 12 h
Working range:
10...2000 mbar absolute
external: -40...+85 °C
internal: -20...+65 °C

Max. deviation:
±2 mbar
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Item no. FP10/020

Item no. FP10/100

Item no. FP10/160

Working range:
0...14 bar absolute
-20...+65 °C

Max. deviation:
±50 mbar
(1...10 bar abs., +25 °C)
only available
externally
Item no. FP7/020

Item no. FP7/100

Item no. FP7/160

Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP9/020

Item no. FP9/100

Item no. FP9/160

Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP3/020

Item no. FP3/100

Item no. FP3/160

Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
only available
externally
Item no. FP4/020

Item no. FP4/100

Item no. FP4/160

Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
only available
externally
Item no. FP8/020

Item no. FP8/100

Item no. FP8/160

Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
only available
externally
Item no. FP12/020

Item no. FP12/100

Item no. FP12/160

3-axis-acceleration
(static)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
Light

1/s to every 12 h
Working range:
0...83'000 lx

Max. sensitivity
at 550 nm
Item no. L3
Item no. FL3/020

Item no. FL3/100

Item no. FL3/160

Connection for
strain gauges
Characteristics:
  • full bridge
  • rated output 1 mV/V
  • bridge voltage 3 V
only available
externally
Item no. FD/020

Item no. FD/100

Item no. FD/160

Analogue inputs
(resolution: 12 bit)

1/s to every 12 h
Input configuration:




only available
externally
Exxxx/020
Exxxx/100
Exxxx/160
Input configuration:




only available
externally
Exxxx/020
Exxxx/100
Exxxx/160
Control terminal Characteristics:
  • Alarm output
  • Input for starting and
    stopping data recording
  • 3 V voltage output
only available
externally
Item no. FY/020
Item no. FY/100
Item no. FY/160
FlexConnector
(only combined with
B22 and B23 cases)
The appropriate
FlexSensors are below
presented for choice.
only available
externally
Item no. FX/020
Item no. FX/100
Item no. FX/160

3. Choose the FlexSensors if required.

If you have selected a FlexConnector or already own an MSR145WD data logger with a FlexConnector, you can order suitable sensors here. Please note only one interchangeable FlexSensor can be connected to the FlexConnector at a time.

Measured parameter /
Measurement/
storage rate
Technical data Item no.
Temperature

1/s to every 12 h
Working range:
-40...+125 °C

Max. deviation:
±0.1 °C (-25...+55 °C)
±0.3 °C (-40...+125 °C)
FXT9/160
Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
-40...+125 °C

Max. deviation:
±2 % rel. humidity
(10...80 %, +25 °C)
±3 % rel. Feuchte
(80...100 %, +25 °C)
FXH3/160
Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP9/160
Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP3/160
Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
FXP4/160
Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
FXP8/160
Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
FXP12/160
3-axis-acceleration
with Fast Peak
(800 Hz)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
FXA4/160
Light

1/s to every 12 h
Working range:
0...83 000 lx

Max. sensitivity at 550 nm
FXL3/160

4. Do you require a base station to transmit the measured values to the MSR SmartCloud?

MSR base station Description Item no.
The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR Smart Cloud.

The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud.

N10115

5. The use of MSR SmartCloud.

The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145WD data logger you will automatically receive the access code to MSR SmartCloud.

Service Description
MSR SmartCloud Free access to MSR SmartCloud when you purchase the MSR145WD data logger.
Data capacity up to 100,000 measurements, Data memory up to three months.

6. Contact us for prices and delivery terms!

Make a price enquiry by telephone, fax or e-mail

The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please have the codes ready.

Warning: Undefined variable $companyName in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 1197
Phone: Warning: Undefined variable $phoneNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 1198
Fax: Warning: Undefined variable $faxNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 1199
E-mail: Warning: Undefined variable $emailAddress in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/sv/msr145wd.php on line 1200

Product codes:

Making price enquiries using the contact form

Please provide us with your contact details on the following online form and send your enquiry with a click of your mouse – we will be pleased to send you a no-obligation quotation!

Title*  
First name    
Surname*    
Company    
Number, street    
Zip code/postcode    
City    
Country*    
Phone    
Fax    
E-mail*    
 
Notes (please enter the number of units you require here):
 

*Mandatory fields

7. General technical data of the MSR145WD.

Memory capacity: Over 1 000 000 measured values.
Key button: With the button you can activate and deactivate the display, the BLE-module and the data recording.
LED:  
Blue:
Red:
Yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply: Lithium-polymer battery, rechargeable via the USB connection
OLED display: High-contrast, brilliant OLED (organic light-emitting diode) colour display
to show data and graphical charts, resolution 96 x 64 pixels.
Interface: USB, Bluetooth Low Energy
PC software: Free Setup, Reader, Viewer and Online software (Windows 7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed.
Operation conditions:
Temperature: -20...+65 °C
Storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145WD complies with EU-Directives RoHS/WEEE.