Warning: Undefined array key "ver" in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 3 Warning: Cannot modify header information - headers already sent by (output started at /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php:3) in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 280 Warning: Undefined variable $redirectUrl in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 282 MSR Electronics GmbH

MSR160: High Speed Data Logger with 4 Analogue Inputs and Gigantic Memory Capacity

Four integrated analogue inputs, a high measurement rate of 1000/s per channel and its gigantic memory capacity, all packed into a small format are the key characteristics of the swiss made MSR160 data logger.

4 analogue inputs for conventional sensors

The analogue inputs of the logger can be used for conventional sensors with analogue outputs (e.g. voltage, current, CO2 etc). The analogue inputs allow voltage and milliamp current to be measured at high data rates up to 1,000 readings per second. A multiple output switching power supply is also provided. Optionally, the MSR160 can be fitted with additional temperature, humidity, pressure, acceleration or light sensors.

Product features data logger MSR160

  • Multi-purpose mini data logger with 4 analogue inputs with freely selectable input configuration (see Configurator) for connecting conventional sensors with analogue output
  • Measuring/storage up to 1000/s per channel
  • Up to 5 additional internal sensors available for temperature, humidity, air pressure and attitude (see Configurator)
  • Up to 2 internal sensors can be replaced with external ones (see Configurator)
  • Stores up to 2 m or 1 bn (SDcard) total readings
  • Lithium-polymer battery (1000 mAh), rechargeable via USB port
  • Small in size, rugged anodised aluminium case, PC
  • Free MSR PC software: MSR Setup, Reader, Viewer and Online software

Configure your own custom MSR160 variant here!

With a few clicks you are able to select and request a no-obligation quotation of your desired MSR160.

1. Basic specification and technical data for the MSR160

Housing
Technical data Item no.
Data Logger MSR160: anodised aluminium case, PC
Standard IP 60
PC, not encapsulated
Analogue inputs: 4 analogue inputs with freely selectable input configuration: 0...20 mA; 4...20 mA; 0...3.0 V; 0.5...4.5 V; 0...5.0 V; 1.0...6.0 V; 0...10.0 V; 0...12.0 V; 0...24.0 V; 0...36.0 V; 0...48.0 V; Resolution: 12 bit
Measurement/storage rate: 1000/s per channel to every 12h
 
Housing: Anodised aluminium case, PC
Size & weight: 39 x 23 x 72 mm, approx. 80 g
Colour: Blue, anthracite
 
Medium: Air, various liquids
Key: Configurable pushbutton functions
Memory capacity: Over 2 Mio. measurement parameters, expandable to over 1 bn with optional microSD card.
 
Power supply: Rechargeable lithium polymer battery 900 mAh
Interface: USB
PC software: Setup, Reader, Viewer and Online software (Windows 7/8/10)

160B7

Data Logger MSR160: anodised aluminium case, PC
Waterproof IP 67
PC, encapsulated

160B8

2. Select the input configuration.

Analogue inputs Inputs Input configuration Item no.
Screw terminal for 4 analogue inputs.

Including alarm output and input
for starting and stopping data recording.
4 analogue inputs
(resolution: 12 bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V
(8)   0...36.0 V
(9)   0...48.0 V

Exxxx

3. Select the sensors.

You can select various internal as well external sensors.

Measured parameter /
Measuring/storage rate
Working range /
Accuracy
Internal
sensor
External sensor (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
external: -40...+125 °C
intern: -20...+65 °C

±0.1 °C (-25...+55 °C)
±0.3 °C (-40...+125 °C)
Item no. T9
Item no. FT9/020
Item no. FT9/100
Item no. FT9/160
-55...+125 °C
±0.5 °C (-10...+70 °C)
±2 °C (-55...+125 °C)
only available
externally
Item no. FT2/020
Item no. FT2/100
Item no. FT2/160
Relative humidity
with integrated temperature

1/s to every 12 h
0...100 % rel. humidity
extern: -40...+125 °C
intern: -20...+65 °C

±2 % rel. humidity
(10...80 %, +25 °C)
±3 % rel. Feuchte
(80...100 %, +25 °C)
Item no. H3
Item no. FH3/020
Item no. FH3/100
Item no. FH3/160
Air pressure absolute,
with integrated temperature

1/s to every 12 h
10...2000 mbar absolute
extern: -40...+85 °C
intern: -20...+65 °C

±2 mbar
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Item no. FP10/020
Item no. FP10/100
Item no. FP10/160
0...14 bar absolute
-20...+65 °C

±50 mbar
(1...10 bar abs., +25 °C)
Item no. P7
Item no. FP7/020
Item no. FP7/100
Item no. FP7/160
Attitude

1/s to every 12 h
±15 g
-20...+65 °C

±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Item no. FA/020
Item no. FA/100
Item no. FA/160
Light

1/s to every 12 h
0...83 000 lx
max. sensitivity
at 550 nm
Item no. L3
Item no. FL3/020
Item no. FL3/100
Item no. FL3/160

4. Would you like to expand the memory capacity of your MSR160 to over 1 billion measurement parameters?

Please order the expansion slot for plugging-in a standard microSD card here. Item no.
Expansion slot for microSD card (includes one formatted and ready for use ≥4GB microSD card). Please note that this expansion slot with plugged-in microSD-card only meets the protection category IP60. N10006

5. Contact us for prices and delivery terms!

Make a price enquiry by telephone, fax or e-mail

The following codes denote the type of datalogger and sensors you have selected. When making price enquiries by telephone, fax or e-mail, please have the codes ready.

Warning: Undefined variable $companyName in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 1014
Phone: Warning: Undefined variable $phoneNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 1015
Fax: Warning: Undefined variable $faxNumber in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 1016
E-mail: Warning: Undefined variable $emailAddress in /home/httpd/vhosts/msr.ch/httpdocs/msr.ch/affiliate/en/msr160.php on line 1017

Product codes:

Making price enquiries using the contact form

Please provide us with your contact details on the following online form and send your enquiry with a click of your mouse – we will be pleased to send you a no-obligation quotation!

Title*  
First name    
Surname*    
Company    
Number, street    
Zip code/postcode    
City    
Country*    
Phone    
Fax    
E-mail*    
 
Notes (please enter the number of units you require here):
 

*Mandatory fields